SYNTOLOGY HomeExplorerAtlasCodeMethodologyAboutDevelopersFeedPricing
Paper · 2002.05115 · 2020

Machine-Learning-Based Diagnostics of EEG Pathology

arXiv · PDF · Open in the Atlas

Code that ran

1 of 1 samples (functions and classes) lifted from this paper's linked repositories executed on a synthesized input in Syntology's jail (0 of them constructed an object rather than computing a result; 0 honoured the contract we drafted, 0 violated it and 0 have no contract verdict; 1 failure of our instrument; 0 no recorded run), measured 2026-11-21; repository links from the Papers with Code archive attributed under CC BY-SA, no affiliation; bodies inline only under a permissive licence as GitHub detects it. Not a reproduction of the paper's results.

"Ran" means the function executed on a synthesized input and returned a value. It is not a reproduction of the paper's results. This record, dated, as JSON: /api/ran/2002.05115.json · badge: /api/ran/2002.05115.svg

Each repository's role is a label: a classifier's output recorded on the link, or, where no role is recorded, what the Papers with Code archive marked. The line under it names its basis. Neither says who wrote the code.

RepositoryRoleRan
gemeinl/auto-eeg-diagnosis-comparison canonical (classifier label)
classifier basis: classifier_2025
1 ran · 0 no recorded run
FunctionStatusWhere it lives
nll_loss_on_mean Ran
ran; the contract check could not run (RAISES, DEP_MISSING or TIMEOUT)
gemeinl/auto-eeg-diagnosis-comparison/code/tuh_auto_diag.py
pointer only (licence: NONE) · get_code("535d2e55e67ae2be")
How it ran

The body of this sample is withheld: GitHub detected no licence in this paper's repository, gemeinl/auto-eeg-diagnosis-comparison when it was checked. The setup block that called it is withheld with it, because it is written against that body. source_path and origin say where the code lives, to read under the repository's own terms. A run is recorded.

Also present in other papers' code

Of 1 samples lifted from this paper's linked repositories, 1 carry a function identity and 0 do not. Of the 1 distinct functions with an identity, 0 are also present in other papers whose code we hold (0 with at least one paper dated earlier, 0 the same month, 0 later) and 1 are only here among the 52,977 papers whose code Syntology holds (as of 2026-09-26).

Only here means: among the 52,977 papers whose code Syntology holds (51,887 with lifted samples, 1,090 through their assemblies only), as of 2026-09-26, no other paper's lifted samples or current assembly bricks contain an identical function body after normalisation.

Presence, not direction: an identical function body in two papers' repositories does not say who wrote it, which came from which, or that either paper's method rests on it. Matching is exact after normalisation, so a renamed or edited function is not matched. Dates are when papers appeared, not when code was written. Only .py files the harvester lifted are covered; notebooks are not read. A new-style arXiv id YYMM.NNNN dates a paper to the month 20YY-MM; otherwise Paper.year dates it to the year; otherwise it is undated. Dates are when the paper appeared, not when the code was written. Read 2026-11-21.

Repositories linked to this paper

Some links come from the archived Papers with Code dataset (CC BY-SA 4.0): attribution and licence.

Abstract

Machine learning (ML) methods have the potential to automate clinical EEG analysis. They can be categorized into feature-based (with handcrafted features), and end-to-end approaches (with learned features). Previous studies on EEG pathology decoding have typically analyzed a limited number of features, decoders, or both. For a I) more elaborate feature-based EEG analysis, and II) in-depth comparisons of both approaches, here we first develop a comprehensive feature-based framework, and then compare this framework to state-of-the-art end-to-end methods. To this aim, we apply the proposed feature-based framework and deep neural networks including an EEG-optimized temporal convolutional network (TCN) to the task of pathological versus non-pathological EEG classification. For a robust comparison, we chose the Temple University Hospital (TUH) Abnormal EEG Corpus (v2.0.0), which contains approximately 3000 EEG recordings. The results demonstrate that the proposed feature-based decoding framework can achieve accuracies on the same level as state-of-the-art deep neural networks. We find accuracies across both approaches in an astonishingly narrow range from 81--86\%. Moreover, visualizations and analyses indicated that both approaches used similar aspects of the data, e.g., delta and theta band power at temporal electrode locations. We argue that the accuracies of current binary EEG pathology decoders could saturate near 90\% due to the imperfect inter-rater agreement of the clinical labels, and that such decoders are already clinically useful, such as in areas where clinical EEG experts are rare. We make the proposed feature-based framework available open source and thus offer a new tool for EEG machine learning research.

For agents

The same record, over MCP at https://syntology.ai/mcp:

get_harvested_code_for_paper("2002.05115")
get_code_for_paper("2002.05115")
have("2002.05115")

The run record, dated, one paper per request, free:

curl https://syntology.ai/api/ran/2002.05115.json

A badge for a README (the split and the date, never a ratio):

[![Syntology run record](https://syntology.ai/api/ran/2002.05115.svg)](https://syntology.ai/paper/2002.05115)

Connect an agent — have() is free.