Puneet Dokania, Kemal Oksuz, Jonathan Sadeghi, Selim Kuzucu
2 of 2 samples (functions and classes) lifted from this paper's linked repositories executed on a synthesized input in Syntology's jail (1 of them constructed an object rather than computing a result; 0 honoured the contract we drafted, 0 violated it and 1 has no contract verdict; 1 failure of our instrument; 0 no recorded run), measured 2026-11-22; bodies inline only under a permissive licence as GitHub detects it. Not a reproduction of the paper's results.
"Ran" means the function executed on a synthesized input and returned a value. It is not a reproduction of the paper's results. This record, dated, as JSON: /api/ran/2405.20459.json · badge: /api/ran/2405.20459.svg
Each repository's role is a label: a classifier's output recorded on the link, or, where no role is recorded, what the Papers with Code archive marked. The line under it names its basis. Neither says who wrote the code.
| Repository | Role | Ran |
|---|---|---|
| fiveai/detection_calibration | community Papers with Code archive |
2 ran · 0 no recorded run |
| Function | Status | Where it lives |
|---|---|---|
| PlattScaling | Ran ran on a synthesized input · constructed an object; no result was computed |
fiveai/detection_calibration/src/detection_calibration/platt_scaling.py pointer only (licence: NOASSERTION) · get_code("cf41e51c2aab32de") How it ranThe body of this sample is withheld: GitHub could not classify the licence of this paper's repository, fiveai/detection_calibration (NOASSERTION). The setup block that called it is withheld with it, because it is written against that body. source_path and origin say where the code lives, to read under the repository's own terms. A run is recorded. |
| quality_focal_loss | Ran ran; our contract draft was wrong, not the code |
fiveai/detection_calibration/src/detection_calibration/platt_scaling.py pointer only (licence: NOASSERTION) · get_code("d02245aaa3768c5f") How it ranThe body of this sample is withheld: GitHub could not classify the licence of this paper's repository, fiveai/detection_calibration (NOASSERTION). The setup block that called it is withheld with it, because it is written against that body. source_path and origin say where the code lives, to read under the repository's own terms. A run is recorded. |
Of 2 samples lifted from this paper's linked repositories, 2 carry a function identity and 0 do not. Of the 2 distinct functions with an identity, 0 are also present in other papers whose code we hold (0 with at least one paper dated earlier, 0 the same month, 0 later) and 2 are only here among the 52,977 papers whose code Syntology holds (as of 2026-09-26).
Only here means: among the 52,977 papers whose code Syntology holds (51,887 with lifted samples, 1,090 through their assemblies only), as of 2026-09-26, no other paper's lifted samples or current assembly bricks contain an identical function body after normalisation.
Presence, not direction: an identical function body in two papers' repositories does not say who wrote it, which came from which, or that either paper's method rests on it. Matching is exact after normalisation, so a renamed or edited function is not matched. Dates are when papers appeared, not when code was written. Only .py files the harvester lifted are covered; notebooks are not read. A new-style arXiv id YYMM.NNNN dates a paper to the month 20YY-MM; otherwise Paper.year dates it to the year; otherwise it is undated. Dates are when the paper appeared, not when the code was written. Read 2026-11-22.
Some links come from the archived Papers with Code dataset (CC BY-SA 4.0): attribution and licence.
Reliable usage of object detectors require them to be calibrateda crucial problem that requires careful attention. Recent approaches towards this involve (1) designing new loss functions to obtain calibrated detectors by training them from scratch, and (2) post-hoc Temperature Scaling (TS) that learns to scale the likelihood of a trained detector to output calibrated predictions. These approaches are then evaluated based on a combination of Detection Expected Calibration Error (D-ECE) and Average Precision. In this work, via extensive analysis and insights, we highlight that these recent evaluation frameworks, evaluation metrics, and the use of TS have notable drawbacks leading to incorrect conclusions. As a step towards fixing these issues, we propose a principled evaluation framework to jointly measure calibration and accuracy of object detectors. We also tailor efficient and easy-to-use post-hoc calibration approaches such as Platt Scaling and Isotonic Regression specifically for object detection task. Contrary to the common notion, our experiments show that once designed and evaluated properly, post-hoc calibrators, which are extremely cheap to build and use, are much more powerful and effective than the recent train-time calibration methods. To illustrate, D-DETR with our post-hoc Isotonic Regression calibrator outperforms the recent train-time state-of-the-art calibration method Cal-DETR by more than 7 D-ECE on the COCO dataset. Additionally, we propose improved versions of the recently proposed Localization-aware ECE and show the efficacy of our method on these metrics. Code is available at: https://github.com/fiveai/detection_calibration.
The same record, over MCP at https://syntology.ai/mcp:
get_harvested_code_for_paper("2405.20459")
get_code_for_paper("2405.20459")
have("2405.20459")
The run record, dated, one paper per request, free:
curl https://syntology.ai/api/ran/2405.20459.json
A badge for a README (the split and the date, never a ratio):
[](https://syntology.ai/paper/2405.20459)
Connect an agent — have() is free.