Elena Offenberg, Dirk Keller, Mariska Vansteensel, Zachary Freudenburg, Nick Ramsey, Julia Berezutskaya, † Contribution
2 of 3 samples (functions and classes) lifted from this paper's linked repositories executed on a synthesized input in Syntology's jail (0 of them constructed an object rather than computing a result; 1 honoured the contract we drafted, 0 violated it and 0 have no contract verdict; 1 failure of our instrument; 1 no recorded run), measured 2026-11-23; bodies inline only under a permissive licence as GitHub detects it. Not a reproduction of the paper's results.
"Ran" means the function executed on a synthesized input and returned a value. It is not a reproduction of the paper's results. This record, dated, as JSON: /api/ran/2605.19646.json · badge: /api/ran/2605.19646.svg
Each repository's role is a label: a classifier's output recorded on the link, or, where no role is recorded, what the Papers with Code archive marked. The line under it names its basis. Neither says who wrote the code.
| Repository | Role | Ran |
|---|---|---|
| UMCU-RIBS/BCI-sift | canonical (classifier label) classifier basis: census |
2 ran · 1 no recorded run |
| Function | Status | Where it lives |
|---|---|---|
| load_config | Ran ran; our contract draft was wrong, not the code |
UMCU-RIBS/BCI-sift/dataset/utils.py code served (permissive licence) · get_code("a75efd435efe8a18") How it ranRan in Syntology's sandbox on this synthesized input (drafted by a language model, Claude Haiku 4.5, prompt python_fixture_v1, through the batch API) and returned dict. The image it ran in was not recorded. If your copy returns the same type on these inputs, it matched what we observed; nothing here checks that. It does NOT mean the output is correct: nothing has compared it to the paper.
|
| sec2ind | Ran ran, honoured the contract we drafted |
UMCU-RIBS/BCI-sift/dataset/utils.py code served (permissive licence) · get_code("07f52d05c34ef820") How it ranRan in Syntology's sandbox on this synthesized input (drafted by a language model, Claude Haiku 4.5, prompt python_fixture_v1, through the batch API) and returned int, ndim 0, dtype family int, shape () as a later run recorded it. The image it ran in was not recorded. If your copy returns the same type, ndim and shape on these inputs, it matched what we observed; nothing here checks that. It does NOT mean the output is correct: nothing has compared it to the paper.
|
| load_by_id | Not yet run unverified (harvested, no recorded run) |
UMCU-RIBS/BCI-sift/dataset/utils.py code served (permissive licence) · get_code("fae4322690bd0b8d") How it ranno invocation recorded. |
Of 3 samples lifted from this paper's linked repositories, 3 carry a function identity and 0 do not. Of the 3 distinct functions with an identity, 0 are also present in other papers whose code we hold (0 with at least one paper dated earlier, 0 the same month, 0 later) and 3 are only here among the 52,977 papers whose code Syntology holds (as of 2026-09-26).
Only here means: among the 52,977 papers whose code Syntology holds (51,887 with lifted samples, 1,090 through their assemblies only), as of 2026-09-26, no other paper's lifted samples or current assembly bricks contain an identical function body after normalisation.
Presence, not direction: an identical function body in two papers' repositories does not say who wrote it, which came from which, or that either paper's method rests on it. Matching is exact after normalisation, so a renamed or edited function is not matched. Dates are when papers appeared, not when code was written. Only .py files the harvester lifted are covered; notebooks are not read. A new-style arXiv id YYMM.NNNN dates a paper to the month 20YY-MM; otherwise Paper.year dates it to the year; otherwise it is undated. Dates are when the paper appeared, not when the code was written. Read 2026-11-23.
Some links come from the archived Papers with Code dataset (CC BY-SA 4.0): attribution and licence.
Advancements in Brain-Computer Interfaces (BCIs) for clinical applications rely on precise and reliable signal interpretation. However, the high-dimensional and noisy nature of data captured from both implanted and nonimplanted BCIs presents significant challenges, necessitating the use of sophisticated filtering techniques, such as feature selection algorithms. We introduce the Python-based BCI-sift (BCI Systematic and Interpretable Feature Tuning) Toolbox, a comprehensive tool designed to streamline the application of diverse optimization algorithms to BCI datasets for identifying the most relevant features in machine learning tasks. Approach Our scikit-learn-compatible toolbox (github.com/UMCU-RIBS/BCI-sift) simplifies feature selection in BCI tasks by integrating advanced optimization methods. It was validated on data from eight able-bodied participants implanted with 64 to 128 high-density electrocorticography (HD ECoG) electrodes. The electrodes were placed on the sensorimotor cortex (SMC), and participants repeatedly spoke 12 different words. BCI-sift successfully identified informative neural features across time points, electrodes, and frequency dimensions. The anatomical locations of electrode selections were consistent across participants and aligned with the functional and anatomical organization of motor activity in the SMC. The most relevant time points were determined to be during word pronunciations. In the frequency dimension, BCI-sift identified the high frequency band as most informative for classification, consistent with prior research. Beyond providing interpretability, BCIsift significantly improved classification accuracy compared to using no feature selection in all dimensions. Significance With BCI-sift, we provide an accessible and versatile platform for feature selection in BCI research, enabling improved classification accuracy, automatic feature analysis, and enhanced interpretability. Although validated with HD ECoG data, the underlying principles are applicable to other data, including implanted and non-implanted BCIs. We encourage researchers to explore and apply BCI-sift in these contexts as well. By enhancing classification accuracy and interpretability, BCI-sift addresses key challenges in developing efficient and transparent BCI systems.
The same record, over MCP at https://syntology.ai/mcp:
get_harvested_code_for_paper("2605.19646")
get_code_for_paper("2605.19646")
have("2605.19646")
The run record, dated, one paper per request, free:
curl https://syntology.ai/api/ran/2605.19646.json
A badge for a README (the split and the date, never a ratio):
[](https://syntology.ai/paper/2605.19646)
Connect an agent — have() is free.