SYNTOLOGY HomeExplorerAtlasCodeMethodologyAboutDevelopersFeedPricing
Paper · 2608.12086 · 2026

Look What the Probes Dragged In! Real-World Chest X-ray Shortcuts in MedCLIP

Théo Sourget, Veronika Cheplygina, Nikolette Pedersen, Regitze Sydendal

arXiv · PDF · Open in the Atlas

Code that ran

We lifted 2 functions out of this paper's own repositories and ran 1 of them in a sandbox. "Ran" means the function executed on a synthesized input and returned a value. It is not a reproduction of the paper's results.

RepositoryRoleRan
nikodice4/MedCLIP_shortcuts canonical 1 of 2
FunctionStatusWhere it lives
resume Ran nikodice4/MedCLIP_shortcuts/src/models/checkpointing.py
code served (permissive licence) · get_code("ed88e3afe0a0eb37")
bootstrap_band Not yet run nikodice4/MedCLIP_shortcuts/src/models/plotting_all.py
code served (permissive licence) · get_code("52286c8baaad256a")

Repositories linked to this paper

Some links come from the archived Papers with Code dataset (CC BY-SA 4.0): attribution and licence.

Abstract

Vision-language models, such as contrastive language-image pre-training (CLIP)-based approaches, have reached state-of-the-art (SOTA) results in medical artificial intelligence. However, recent work reveals that CLIP-based models remain vulnerable to shortcuts. We investigate how real-world shortcuts manifest across different layers of the medical CLIPbased model, MedCLIP, and its vision encoder, a frozen ResNet-50. We attach 17 linear classification probes to the intermediate layers of the ResNet-50 and train them on three different dataset configurations and targets: NIH-CXR14 (pneumothorax) and PadChest (cardiomegaly and pneumothorax). This setup allows us to observe model behaviour during evaluation using subgroup-based calibration and layer-wise confidence curves. We find that the final linear probes achieve a high AUROC but poor calibration in the models. The layer-wise confidence analyses suggest that shortcuts emerge at different depths. Patterns consistent with localised shortcuts, such as drains, appear at later layers, while patterns consistent with diffuse shortcuts, such as scanner-specific noise patterns, emerge earlier, aligning with previous work. Finally, we conduct a manual analysis of the images, which reveals data quality issues in both NIH-CXR14 and PadChest. Our findings underscore that even SOTA models remain vulnerable to shortcuts, and the need for high-quality and wellannotated datasets to draw solid conclusions. Code can be found on our GitHub: https://github.com/nikodice4/MedCLIP_shortcuts.