Mubarak Shah, Hai Nguyen, Kunyang Li, Pegah Khosravi, Chenguang Zhao, Joshua Lowe, Peace C. Madueme, Mehdi Hedjazi Moghari, Yuzhang Zhang
We have not lifted any functions out of this paper's repositories yet, so there is nothing we have run. The repositories linked to it are listed below.
Some links come from the archived Papers with Code dataset (CC BY-SA 4.0): attribution and licence.
Cardiovascular magnetic resonance (CMR), including cine imaging, is a reference standard for the noninvasive assessment of cardiac morphology and ventricular function. Cine CMR interpretation integrates qualitative visual assessment with quantitative measurements of ventricular volumes, ejection fraction, myocardial mass, wall thickness, and regional wall motion. Current medical vision-language models (VLMs) cannot reliably derive quantitative measurements from multidimensional cine images without analysis tools. We present CineMR, a tool-augmented VLM that invokes cardiac image-analysis tools and integrates their outputs into interleaved reasoning for quantitative CMR assessment. We also construct a multi-cohort visual question answering benchmark covering quantitative metric extraction, multiclass diagnosis, and differential diagnosis, together with tools for segmentation, phase selection, volumetry, morphometry, and regional wall motion analysis. CineMR is trained with supervised fine-tuning (SFT) on tool-interaction traces followed by Group Relative Policy Optimization (GRPO) with conditional tool-use rewards. On the multi-cohort cine CMR benchmark, CineMR achieves 35.9% pass@1 and 58.9% pass@4, compared with 1.5% pass@1 for the Qwen3-VL-8B backbone and 0.0% and 7.0% pass@1 for LLaVA-Med v1.5 and MedGemma-4B, respectively. Correct tool invocation reaches 99.8% after GRPO, up from 78.9% after SFT. Live tool outputs improve ventricular measurement accuracy by 20.4--23.7% over direct model predictions, and removing all tools reduces pass@1 from 35.9% to 27.9%. These results highlight the importance of reliable tool use for quantitative cine CMR reasoning and support CineMR as a promising approach for assistive cardiac image assessment. Code, benchmark resources, and model weights are available at https://github.com/AI-MIND-Lab/CineMR.
The same record, over MCP at https://syntology.ai/mcp:
get_harvested_code_for_paper("2610.01166")
get_code_for_paper("2610.01166")
have("2610.01166")
The run record, dated, one paper per request, free:
curl https://syntology.ai/api/ran/2610.01166.json
A badge for a README (the split and the date, never a ratio):
[](https://syntology.ai/paper/2610.01166)
Connect an agent — have() is free.